Please wait a minute...
Frontiers of Chemical Science and Engineering

ISSN 2095-0179

ISSN 2095-0187(Online)

CN 11-5981/TQ

邮发代号 80-969

2019 Impact Factor: 3.552

Frontiers of Chemical Science and Engineering  2012, Vol. 6 Issue (3): 270-275   https://doi.org/10.1007/s11705-012-1298-x
  RESEARCH ARTICLE 本期目录
Determination of aniline derivatives in water samples after preconcentration with oxidized multiwalled carbon nanotubes as solid-phase extraction disk
Determination of aniline derivatives in water samples after preconcentration with oxidized multiwalled carbon nanotubes as solid-phase extraction disk
Hideyuki KATSUMATA1(), Yuta ODA1, Satoshi KANECO1, Tohru SUZUKI2, Kiyohisa OHTA1
1. Department of Chemistry for Materials, Graduate School of Engineering, Mie University, Tsu 514-8507, Japan; 2. Environmental Preservation Center, Mie University, Tsu 514-8507, Japan
 全文: PDF(151 KB)   HTML
Abstract

A sensitive and selective preconcentration method using solid-phase extraction (SPE) disk made from oxidized multiwalled carbon nanotubes (OMWCNTs), has been developed for the determination of aniline derivatives, such as 2-nitroaniline (2-NA), 4-nitroaniline (4-NA), and 2,4-dichloroaniline (2,4-DCA) in water samples. Anilines were extracted onto OMWCNT disk and then determined by high performance liquid chromatography (HPLC) with UV detector. Several parameters on the recovery of the analytes were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 8 using 200 mL of validation solution containing 2 μg of anilines and 10 mL of acetonitrile/ethanol (8/2, v/v) as an eluent. Relative standard deviations for five determinations were 7.5% (2-NA), 6.5% (4-NA) and 3.8% (2,4-DCA) under optimum conditions. The linear range of calibration curves were 0.5 ng·mL-1 to 15 ng·mL-1 for each analyte with good correlation coefficients. The detection limits (3S/N) of 2-NA, 4-NA and 2,4-DCA were 30 pg·mL-1, 31 pg·mL-1 and 26 pg·mL-1, respectively. Our method was successfully applied to the determination of aniline compounds in river water sample with high precision and accuracy.

Key wordsaniline determination    solid-phase extraction    oxidized multiwalled carbon nanotubes    water sample    HPLC-UV
收稿日期: 2012-02-09      出版日期: 2012-09-05
Corresponding Author(s): KATSUMATA Hideyuki,Email:hidek@chem.mie-u.ac.jp   
 引用本文:   
. Determination of aniline derivatives in water samples after preconcentration with oxidized multiwalled carbon nanotubes as solid-phase extraction disk[J]. Frontiers of Chemical Science and Engineering, 2012, 6(3): 270-275.
Hideyuki KATSUMATA, Yuta ODA, Satoshi KANECO, Tohru SUZUKI, Kiyohisa OHTA. Determination of aniline derivatives in water samples after preconcentration with oxidized multiwalled carbon nanotubes as solid-phase extraction disk. Front Chem Sci Eng, 2012, 6(3): 270-275.
 链接本文:  
https://academic.hep.com.cn/fcse/CN/10.1007/s11705-012-1298-x
https://academic.hep.com.cn/fcse/CN/Y2012/V6/I3/270
Fig.1  
Fig.2  
Fig.3  
Fig.4  
Fig.5  
CompoundsLinear range a) /(ng·mL-1)Linearity /R2Detection limit b) /( pg·mL-1)Recovery c) /% (n = 5)RSD / % (n = 5)
2-NA0.5 - 150.9943088±37.5
4-NA0.5 - 150.9983181±76.5
2,4-DCA0.5 - 150.9862695±53.8
Tab.1  
Fig.6  
CompoundsConcentration /(ng·mL-1)Recovery /%
SpikedFound a)
2-NA-n.d.
10.010.8±1.2108
4-NA-n.d.
10.010.7±2.4107
2,4-DCA-n.d.
10.09.8±2.498
Tab.2  
1 Voyksner R D, Straub R, Keever J T, Freeman H S, Hsu W N. Determination of aromatic-amines originating from azo dyes by chemical-reduction combined with liquid-chromatography mass-spectrometry. Environmental Science & Technology , 1993, 27(8): 1665–1672
doi: 10.1021/es00045a025
2 Kataoka H. Derivatization reactions for the determination of amines by gas chromatography and their applications in environmental analysis. Journal of Chromatography. A , 1996, 733(1–2): 19–34
doi: 10.1016/0021-9673(95)00726-1 pmid:8814790
3 Laha S, Luthy R G. Oxidation of aniline and other primary aromatic amines by manganese dioxide. Environmental Science & Technology , 1990, 24(3): 363–373
doi: 10.1021/es00073a012
4 Dasgupta A. Gas chromatographic-mass spectrometric identification and quantification of aniline after extraction from serum and derivatization with 2,2,2-trichloroethyl chloroformate, a novel derivative. Journal of Chromatography. B, 1998, 716(1–2): 354– 358
doi: 10.1016/S0378-4347(98)00286-2 pmid:9824251
5 Huang M J, Tai C, Zhou Q F, Jiang G B. Preparation of polyaniline coating on a stainless-steel wire using electroplating and its application to the determination of six aromatic amines using headspace solid-phase microextraction. Journal of Chromatography. A , 2004, 1048(2): 257–262
pmid:15481264
6 Zimmermann T, Ensinger W J, Schmidt T C. In situ derivatization/solid-phase microextraction: determination of polar aromatic amines. Analytical Chemistry , 2004, 76(4): 1028–1038
doi: 10.1021/ac035098p pmid:14961735
7 Kulkarni S, Shearrow A M, Malik A. Sol-gel immobilized short-chain poly(ethylene glycol) coating for capillary microextraction of underivatized polar analytes. Journal of Chromatography. A , 2007, 1174(1–2): 50–62
doi: 10.1016/j.chroma.2007.10.082 pmid:18021792
8 Liu X Y, Ji Y S, Zhang H X, Liu M C. Highly sensitive analysis of substituted aniline compounds in water samples by using oxidized multiwalled carbon nanotubes as an in-tube solid-phase microextraction medium. Journal of Chromatography. A , 2008, 1212(1–2): 10–15
doi: 10.1016/j.chroma.2008.10.034 pmid:18952215
9 Louter A J H, Ramalho S, Vreuls R J J, Jahr I D, Brinkman U. An improved approach for on-line solid-phase extraction gas chromatography. Journal of Microcolumn Seperations , 1996, 8(7): 469–477
doi: 10.1002/(SICI)1520-667X(1996)8:7<469::AID-MCS3>3.0.CO;2-#
10 Bouzige M, Machtalère G, Legeay P, Pichon V, Hennion M C. New methodology for a selective on-line monitoring of some polar priority industrial chemicals in waste water. Waste Management (New York, N.Y.) , 1999, 19(2): 171–180
doi: 10.1016/S0956-053X(99)00010-0
11 Peng J F, Liu J F, Jiang G B, Tai C, Huang M J. Ionic liquid for high temperature headspace liquid-phase microextraction of chlorinated anilines in environmental water samples. Journal of Chromatography. A , 2005, 1072(1): 3–6
doi: 10.1016/j.chroma.2004.11.060 pmid:15881452
12 Zhu L, Tay C B, Lee H K. Liquid-liquid-liquid microextraction of aromatic amines from water samples combined with high-performance liquid chromatography. Journal of Chromatography. A , 2002, 963(1–2): 231–237
doi: 10.1016/S0021-9673(02)00547-2 pmid:12187975
13 Sarafraz-Yazdi A, Es'haghi Z. Comparison of hollow fiber and single-drop liquid-phase microextraction techniques for HPLC determination of aniline derivatives in water. Chromatographia , 2006, 63(11–12): 563–569
doi: 10.1365/s10337-006-0801-2
14 Zhou Q, Jiang G, Liu J, Cai Y. Combination of microporous membrane liquid-liquid extraction and capillary electrophoresis for the analysis of aromatic amines in water samples. Analytica Chimica Acta , 2004, 509(1): 55–62
doi: 10.1016/j.aca.2003.12.017
15 Yazdi A S, Es'haghi Z. Two-step hollow fiber-based, liquid-phase microextraction combined with high-performance liquid chromatography: a new approach to determination of aromatic amines in water. Journal of Chromatography. A , 2005, 1082(2): 136–142
doi: 10.1016/j.chroma.2005.05.102 pmid:16035354
16 Thurman E M, Snavely K. Advances in solid-phase extraction disks for environmental chemistry. Trends in Analytical Chemistry , 2000, 19(1): 18–26
doi: 10.1016/S0165-9936(99)00175-2
17 Tran A T K, Hyne R V, Doble P. Determination of commonly used polar herbicides in agricultural drainage waters in Australia by HPLC. Chemosphere , 2007, 67(5): 944–953
doi: 10.1016/j.chemosphere.2006.11.002 pmid:17184816
18 Riley M B, Dumas J A, Gbur E E, Massey J H, Mattice J D, Mersie W, Mueller T C, Potter T, Senseman S A, Watson E. Pesticide extraction efficiency of two solid phase disk types after shipping. Journal of Agricultural and Food Chemistry , 2005, 53(13): 5079–5083
doi: 10.1021/jf050029s pmid:15969478
19 Katsumata H, Matsumoto T, Kaneco S, Suzuki T, Ohta K. Preconcentration of diazinon using multiwalled carbon nanotubes as solid-phase extraction adsorbents. Microchemical Journal , 2008, 88(1): 82–86
doi: 10.1016/j.microc.2007.10.002
20 Pyrzynska K. Carbon nanotubes as sorbents in the analysis of pesticides. Chemosphere , 2011, 83(11): 1407–1413
doi: 10.1016/j.chemosphere.2011.01.057 pmid:21396677
21 Niu H Y, Cai Y Q, Shi Y L, Wei F S, Liu J M, Jiang G B. A new solid-phase extraction disk based on a sheet of single-walled carbon nanotubes. Analytical and Bioanalytical Chemistry , 2008, 392(5): 927–935
doi: 10.1007/s00216-008-2332-1 pmid:18726089
22 Niu H Y, Shi Y L, Cai Y Q, Wei F S, Jiang G B. Solid-phase extraction of sulfonylurea herbicides from water samples with single-walled carbon nanotubes disk. Mikrochimica Acta , 2009, 164(3–4): 431–438
doi: 10.1007/s00604-008-0079-1
23 Katsumata H, Kojima H, Kaneco S, Suzuki T, Ohta K. Preconcentration of atrazine and simazine with multiwalled carbon nanotubes as solid-phase extraction disk. Microchemical Journal , 2010, 96(2): 348–351
doi: 10.1016/j.microc.2010.06.005
24 Lu C, Chiu H. Adsorption of zinc(II) from water with purified carbon nanotubes. Chemical Engineering Science , 2006, 61(4): 1138–1145
doi: 10.1016/j.ces.2005.08.007
25 Wang H J, Zhou A L, Peng F, Yu H, Chen L F. Adsorption characteristic of acidified carbon nanotubes for heavy metal Pb(II) in aqueous solution. Materials Science and Engineering: A , 2007, 466(1–2): 201–206
doi: 10.1016/j.msea.2007.02.097
26 Muller L, Fattore E, Benfenati E. Determination of aromatic amines by solid-phase microextraction and gas chromatography mass spectrometry in water samples. Journal of Chromatography. A , 1997, 791(1–2): 221–230
doi: 10.1016/S0021-9673(97)00795-4
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed