Please wait a minute...
Frontiers of Chemical Science and Engineering

ISSN 2095-0179

ISSN 2095-0187(Online)

CN 11-5981/TQ

Postal Subscription Code 80-969

2018 Impact Factor: 2.809

Front Chem Eng Chin    2009, Vol. 3 Issue (1) : 93-96    https://doi.org/10.1007/s11705-009-0112-x
RESEARCH ARTICLE
Combined static mixers for high viscous fluids mixing
Zhenhao XI1, Weizhen SUN1, Ling ZHAO1(email.png), Zhaoyan LIU2
1. 1. State Key Laboratory of Chemical Engineering, East China University of Science and Technology, Shanghai 200237, China; 2. 2. Beijing Innovation Polymerization Technology Company, Beijing 100050, China
 Download: PDF(195 KB)   HTML
 Export: BibTeX | EndNote | Reference Manager | ProCite | RefWorks
Abstract

A new static mixer Cross-over-Disc has been invented to strip off the boundary layer and to make strong radial mixing. The pressure drop of Cross-over-Disc is 12—26 times as large as that of empty pipe with equivalent diameter and length. The mixing performance of Cross-over-Disc with 14 elements has been investigated in the viscosity range of 190—250 Pa?s by decoloration method, and the gray analysis of images shows that mixing inhomogeneity is about 7.5% and 9.4% for the mixing ratio of 5∶1 and 10∶1, respectively. Furthermore, mixing inhomogeneity for a combination of static mixing elements (four from Cross-over-Disc and three pairs from Sulzer-type) can be decreased to 2.1%—3.1% within a reasonable range of pressure drop.

Keywords static mixer      Cross-over-Disc      pressure drop      mixing performance      high viscous fluid     
Corresponding Author(s): ZHAO Ling,Email:zhaoling@ecust.edu.cn   
Issue Date: 05 March 2009
 Cite this article:   
Zhenhao XI,Weizhen SUN,Ling ZHAO, et al. Combined static mixers for high viscous fluids mixing[J]. Front Chem Eng Chin, 2009, 3(1): 93-96.
 URL:  
https://academic.hep.com.cn/fcse/EN/10.1007/s11705-009-0112-x
https://academic.hep.com.cn/fcse/EN/Y2009/V3/I1/93
1 Hobbs D M, Muzzio F J. Reynolds number effects on laminar mixing in the Kenics static mixer. Chem Eng J , 1998, 70: 93-103
2 Liu Z Y. Patent CN1490065, 2004-04-21
3 Liu C J, Lu H B, Liu H, Yuan X G. Computational fluid dynamic simulation of the hydrodynamics characteristic in a static mixer. Journal of Tianjin University Science and Technology , 2007, 40(6): 677-682
4 Shah N F, Kale D D. Pressure drop for laminar flow of non-Newtonian fluids in static mixers. Chem Eng Sci , 1991, 46: 2159-2161
doi: 10.1016/0009-2509(91)80175-X
5 Hyun S S, Sang P H. A general correlation for pressure drop in a Kenics static mixer. Chem Eng Sci , 2005, 60: 5696-5704
doi: 10.1016/j.ces.2005.04.084
[1] Minhua ZHANG,Fang MENG,Zhongfeng GENG. CFD simulation on shell-and-tube heat exchangers with small-angle helical baffles[J]. Front. Chem. Sci. Eng., 2015, 9(2): 183-193.
[2] CHEN Yunhua, ZHU Xuedong, WU Yongqiang, ZHU Zibin. The investigation of pressure drop in moving-beds[J]. Front. Chem. Sci. Eng., 2007, 1(2): 184-189.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed