Optimization for operating modes based on simulation of seasonal underground thermal energy storage
Optimization for operating modes based on simulation of seasonal underground thermal energy storage
ZHAO Jun, CHEN Yan, LI Xinguo
School of Mechanical Engineering, Tianjin University;
 全文: PDF(138 KB)   HTML
Abstract:A simulation was performed, which concerned the feasibility of seasonal underground thermal energy storage (UTES) in Tianjin, China. The investigated system consisted of 8 boreholes. In summer, residual solar thermal energy was emitted into the soil surrounding the borehole heat exchangers through which the stored energy was extracted in winter with a ground coupled heat pump (GCHP) to provide a proper heating temperature. A simulation study was performed to study the influence of system operation modes on thermal recovery based on the experimental data of a GCHP system, local meteorological conditions and soil properties in Tianjin. The results indicate a thermal recovery ratio of less than 67% and different temperature distributions under three modes. Finally, an operation mode was suggested based on both lower loss and better thermal recovery in the UTES.
出版日期: 2008-09-05
 引用本文:   
. Optimization for operating modes based on simulation of seasonal underground thermal energy storage[J]. Frontiers of Energy and Power Engineering in China - Selected Publications from Chinese Universities, 2008, 2(3): 298-301.
ZHAO Jun, CHEN Yan, LI Xinguo. Optimization for operating modes based on simulation of seasonal underground thermal energy storage. Front. Energy, 2008, 2(3): 298-301.
 链接本文:  
https://academic.hep.com.cn/fie/CN/10.1007/s11708-008-0053-y
https://academic.hep.com.cn/fie/CN/Y2008/V2/I3/298
1 Chinese Academy ofSciences. . 2005 Strategic Report: China's Sustainable Development. Beijing: Science Press, 2005
2 Sanner B, Karytsas C, Mendrinos D, et al.. Current status of ground source heat pumps andunderground thermal energy storage in Europe. Geothermics, 2003, 32(4–6): 579–588.
doi:10.1016/S0375‐6505(03)00060‐9
3 Nielsen K . Thermalenergy storage a state-of-the-art. A Reportwithin the Research Program “Smart Energy-Efficient Buildingsat NTNU and SINTEF”, 2003
4 Gu Yan, O'Neal D L . Modeling the effect of backfillson U-tube ground coil performance. ASHRAETrans, 1998, 104(2): 46–54
5 Arif H, Ozay A, Ebru H . Experimental study of a closed loop vertical ground sourceheat pump system. Energy Conversion andManagement, 2003, 44(4): 527–548.
doi:10.1016/S0196‐8904(02)00073‐0
6 Zhao Jun . Heat transfer and thermal performance of the vertical downhole heatexchanger for ground source heat pumps. Dissertation for the Doctoral Degree. Tianjin: Tianjin University, 2002
7 Li Xinguo, Chen Yan, Chen Zhihao, et al.. Thermal performances of different types of undergroundheat exchangers. Energy and Buildings, 2006, 38(5): 543–547.
doi:10.1016/j.enbuild.2005.09.002
Viewed