Please wait a minute...
Frontiers in Energy

ISSN 2095-1701

ISSN 2095-1698(Online)

CN 11-6017/TK

邮发代号 80-972

2019 Impact Factor: 2.657

Frontiers of Energy and Power Engineering in China  2009, Vol. 3 Issue (2): 198-203   https://doi.org/10.1007/s11708-009-0004-2
  RESEARCH ARTICLE 本期目录
Steam turbine governor modeling and parameters testing for power system simulation
Steam turbine governor modeling and parameters testing for power system simulation
Ying LI1,2(email.png), Chufeng PENG2, Zenghui YANG2
1. 1. School of Mechanical Engineering, Shanghai Jiaotong University, Shanghai 200240, China;; 2. 2. East China Electric Power Test & Research Institute, Shanghai 200437, China
 全文: PDF(224 KB)   HTML
Abstract

The theoretical modeling, parameters test and model correction for a steam turbine (ST) governor are discussed. A set of ST Governor system model for power system simulation is created based on this research. A power system simulation for an actual power grid accident is conducted using this new model and the comparison between the simulation and actual data show that the results are satisfactory.

Key wordspower system simulation    ST governor system    modeling    parameters testing
收稿日期: 2008-06-25      出版日期: 2009-06-05
Corresponding Author(s): LI Ying,Email:li_ying758@yahoo.com.cn   
 引用本文:   
. Steam turbine governor modeling and parameters testing for power system simulation[J]. Frontiers of Energy and Power Engineering in China, 2009, 3(2): 198-203.
Ying LI, Chufeng PENG, Zenghui YANG. Steam turbine governor modeling and parameters testing for power system simulation. Front Energ Power Eng Chin, 2009, 3(2): 198-203.
 链接本文:  
https://academic.hep.com.cn/fie/CN/10.1007/s11708-009-0004-2
https://academic.hep.com.cn/fie/CN/Y2009/V3/I2/198
Fig.1  
Fig.2  
Fig.3  
Fig.4  
Fig.5  
Fig.6  
Fig.7  
No.unit capacity/MWcontrol mode of HP governing valve
A300sequential
B300synchronous
C600sequential
D900synchronous
Tab.1  
Fig.8  
Fig.9  
Fig.10  
1 Gao Hong, Zhang Jianwen, Wu Fang. Application of system identification theory in electric power system. Shanxi Electric Power , 2001, (5): 51-52 (in Chinese)
2 He Renmu. The study of generator excitation system modeling and parameters estimation. Power System Technology , 2007, 31(14): 62-67
3 Li Peizhi, Lian Hongwei. Power Plant Steam Turbine DEH System. Beijing: Electric Power Publishing of China, 2005
4 Wang Li. Application of automatic generation control system in 300 MW coal-fired power unit. Journal of North China Electric Power University , 2002, 29(1): 109-111
5 de Mello F P. Dynamic models for fossil fueled steam units in power system studies. IEEE Transaction on Power Systems , 1991, 6(2): 753-761
doi: 10.1109/59.76722
6 Pereira L, Undrill J, Kosterev D, . a new thermal governor modeling approach in the WECC. IEEE Transactions on Power Systems , 2003, 18(2): 819-829
doi: 10.1109/TPWRS.2003.811007
7 Borghettia A, Migliavaccab G, Nuccia C A, . Black-start-up simulation of a repowered thermoelectric unit. Control Engineering Practice , 2001, 9(7): 791-803
doi: 10.1016/S0967-0661(01)00034-X
8 Cheres E. Basic Turbine Values from Data of Fault Events. IEEE , 2004