Please wait a minute...
Frontiers in Energy

ISSN 2095-1701

ISSN 2095-1698(Online)

CN 11-6017/TK

邮发代号 80-972

2019 Impact Factor: 2.657

Front. Energy  2010, Vol. 4 Issue (1): 55-65   https://doi.org/10.1007/s11708-009-0082-1
  Research articles 本期目录
Research progress in liquid desiccant air-conditioning devices and systems
Research progress in liquid desiccant air-conditioning devices and systems
Xiaohua LIU,Yi JIANG,Shuanqiang LIU,Xiaoyang CHEN,
Department of Building Science, School of Architecture, Tsinghua University, Beijing 100084, China;
 全文: PDF(504 KB)  
Abstract:The developments on liquid desiccant air-conditioning systems were illustrated and summarized in this paper. In order to obtain a better dehumidification (or humidification) performance, liquid desiccant should be cooled (or heated) rather than air. Two fundamental modules were proposed, including basic spray module with extra heat exchanger and total heat recovery device, which could be combined to set up various kinds of liquid desiccant air processors. The operating principle of heat pump-driven outdoor air processor as well as heat-driven outdoor air processor was analyzed. The COPair of the heat pump (or power)-driven outdoor air processor could be as high as 5.0 both in summer and in winter operating conditions. The COPair of the hot water-driven processor (65°C–80°C) was 1.19 and 0.93, respectively, using evaporative indoor exhaust air or cooling water to cool the dehumidification process. The liquid desiccant air processor-based temperature and humidity-independent control air-conditioning system could save 20%–30% operating energy compared with the conventional air-conditioning system.
Key wordsliquid desiccant    heat and mass transfer    performance    air-conditioning
出版日期: 2010-03-05
 引用本文:   
. Research progress in liquid desiccant air-conditioning devices and systems[J]. Front. Energy, 2010, 4(1): 55-65.
Xiaohua LIU, Yi JIANG, Shuanqiang LIU, Xiaoyang CHEN, . Research progress in liquid desiccant air-conditioning devices and systems. Front. Energy, 2010, 4(1): 55-65.
 链接本文:  
https://academic.hep.com.cn/fie/CN/10.1007/s11708-009-0082-1
https://academic.hep.com.cn/fie/CN/Y2010/V4/I1/55
Waugaman D G, Kini A, Kettleborough C F. A review of desiccant coolingsystems. Journal of Energy Resource Technology, 1993, 115(1): 1–8

doi: 10.1115/1.2905965
Chung T W, Ghosh T K, Hines A L. Comparison between random and structuredpackings for dehumidification of air by lithium chloride solutionsin a packed column and their heat and mass transfer correlations. Industrial and Engineering Chemistry Research, 1996, 35(1): 192–198

doi: 10.1021/ie940652u
Patnaik S, Lenz T G, Lof G O G. Performance studies for an experimentalsolar open-cycle liquid desiccant air dehumidification system. Solar Energy, 1990, 44(3): 123–135

doi: 10.1016/0038-092X(90)90074-M
Fumo N, Goswami D Y. Study of an aqueous lithium chloride desiccant system: air dehumidificationand desiccant regeneration. Solar Energy, 2002, 72(4): 351–361

doi: 10.1016/S0038-092X(02)00013-0
Zhang Lizhi. Dehumidification Technology. Beijing: Chemical Industrial Press, 2005 (in Chinese)
Liu Xiaohua, Jiang Yi. Temperatureand Humidity Independent Control Air-Conditioning System. Beijing: Chinese Architectural and Industrial Press, 2006 (in Chinese)
Chua HT, Toh HK, Malek A, Ng K C, Srinivasan K. Improved thermodynamic propertyfields of LiBr-H2O solution. International Journal of Refrigeration, 2000, 23(6): 412–429

doi: 10.1016/S0140-7007(99)00076-6
Conde M R. Properties of aqueous solutions of lithium and calciumchlorides: formulations for use in air conditioning equipment design. International Journal of Thermal Sciences, 2004, 43(4): 367–382

doi: 10.1016/j.ijthermalsci.2003.09.003
Ren Chengqin. Corrections to the simple effectiveness-NTU method forcounterflow cooling towers and packed bed liquid desiccant-air contactsystems. International Journal of Heatand Mass Transfer, 2008, 51(1―2): 237–245
Yin Yonggao, Zhang Xiaosong, Chen Zhenqian. Experimental study on dehumidifierand regenerator of liquid desiccant cooling air conditioning system. Building and Environment, 2007, 42(7): 2505–2511

doi: 10.1016/j.buildenv.2006.07.009
Kessling W, Laevemann E, Kapfhammer C. Energy storage for desiccantcooling systems component development. Solar Energy, 1998, 64(4―6): 209–221

doi: 10.1016/S0038-092X(98)00081-4
Zhang Xiaosong, Yin Yonggao, Cao Yiran. Experimental study of dehumidificationperformance of liquid desiccant cooling system with energy storage. Journal of Thermal Science and Technology, 2004, 3(1): 60–64 (in Chinese)
Zhao Y. Study on the solar liquid desiccant air-conditioningsystem. Dissertation for the doctoral degree. Nanjing: Department of Power Engineering, Southeast University, 2002
Saman WY, Alizadeh S. Anexperimental study of a cross-flow type plate heat exchanger for dehumidification/cooling. Solar Energy, 2002, 73(1): 59–71

doi: 10.1016/S0038-092X(01)00078-0
Liu Xiaohua, Zhang Yan, Qu Kaiyang, Jiang Yi. Experimental study on mass transfer performances of cross flow dehumidifierusing liquid desiccant. Energy Conversionand Management, 2006, 47(15,16): 2682–2692
Li Weiyi, Dong Yan, Fang Chengchao. The experimental researchof liquid dehumidifying system. Acta EnergiaeSolaris Sinica, 2000, 21(4): 391–395 (in Chinese)
Wu Anming, Li Chunlin, Zhang Hefei. Study on the performanceof internally-cooled liquid desiccant system. Petro-Chemical Equipment, 2006, 35(6): 17–20 (in Chinese)
Lowenstein A, Slayzak S, Kozubal E. A zero carryover liquid-desiccantair conditioner for solar applications. In: ASME International Solar Energy Conference, Denver, CO, 2006
Ahmed C S K, Gandhidasan P, Al-Farayedhi A A. Simulation of a hybrid liquiddesiccant based air-conditioning system. Applied Thermal Engineering, 1997, 17(2): 125–134

doi: 10.1016/S1359-4311(96)00025-7
Rane M V, Reddy S V K, Bajaj J S. Cooling & dehumidification usingliquid desiccant. In: Proceeding of theInternational Sorption Heat Pump Conference, Shanghai, China, 2002
Liu Shuanqiang, Jiang Yi, Xie Xiaoyun, Chen Xiaoyang. System principle and performance of two-stage liquiddesiccant outdoor air processor driven by heat pump. In: International Congress of Refrigeration, Beijing, China, 2007
Xie Xiaoyun, Jiang Yi, Tang Yidan, Yi Xiaoqin, Liu Shuanqiang. Simulation and experimentalanalysis of a fresh air-handling unit with liquid desiccant sensibleand latent heat recovery. Building Simulation, 2008, 1(1): 53–63

doi: 10.1007/s12273-008-8210-0
Chang Xiaomin, Liu Xiaohua, Xie Xiaoyun, Jiang Yi. Winter performance analysis on a liquid desiccant freshair handling unit driven by heat source. HV&AC, 2007, 37(12): 106–110 (in Chinese)
Liu Xiaohua, Li Zhen, Jiang Yi, Lin Borong. Annual performance of liquid desiccant based independent humiditycontrol HVAC system. Applied Thermal Engineering, 2006, 26(11―12): 1198–1207
Liu Xiaohua, Jiang Yi, Yi Xiaoqin. Effect of regeneration mode on the performanceof liquid desiccant packed bed regenerator. Renewable Energy, 2009, 34(1): 209–216

doi: 10.1016/j.renene.2008.03.003
Li Zhen. Principles of thermodynamic analysis of humid air processand its application in liquid desiccant air conditioning systems. Dissertation for the Doctoral Degree. Beijing: Department of Building Science, Tsinghua University, 2005
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed