1.Institute of Heating
Ventilation and Air Conditioning, Tongji University, Shanghai 200092,
China; 2.Department of Mechanical
Engineering, The University of Hong Kong, Hong Kong SAR, China; 3.Department of Building
Science, School of Architecture, Tsinghua University, Beijing 100084,
China; 4.Building Environment
and New Energy Resource Laboratory, Dalian University of Technology,
Dalian 116024, China; 5.School of Architecture,
Xi’an Architectural Technology University, Xi’an 710005,
China;
Abstract:About 67million Chinese kangs are still used by about 175million people in China today. The kang utilizes biomass burning for space heating and hence reduces the use of commercial energy. However, the existing design of kangs is largely based on the accumulated experience of craftsmen, for lack of scientific studies and engineering design guidelines. Poor construction of kangs also leads to serious indoor air pollution. In this paper, a macroscopic smoke flow and heat transfer model of an elevated kang is integrated in a widely-used building energy analysis software in China–DeST, and the integrated software can be used for the thermal performance analysis of kang-integrated houses. A typical house with kangs in various villages of northern China is chosen as a case study. The annual performance of the kang under different insulations of building envelope and climatic conditions are discussed. Based on the simulation results, it is found that the thermal comfort requirement of the outside surface of the upper kang plate can be met by a proper construction of the kang and selection of the appropriate firing pattern. The better the insulation of the building envelope is or the better the room air tightness is, the greater the indoor air temperature rise and the greater the building heating load contribution of the kang. In the eight selected cities in northern China, the use of kang can meet 50%–80% of the house heating load.
. Thermal and energy analysis of a Chinese kang[J]. Front. Energy, 2010, 4(1): 84-92.
Zhi ZHUANG, Yuguo LI, Xudong YANG, Bin CHEN, Jiaping LIU, . Thermal and energy analysis of a Chinese kang. Front. Energy, 2010, 4(1): 84-92.
Men R. Origin of everything. Beijing: China Economy Press, 2004 (in Chinese)
Chen B, Zhuang Z, Chen X, Jia X. Fieldsurvey of indoor thermal environment of rural residences with coupledChinese kang and passive solar wall heating in northeast China. Solar Energy, 2007, 81(6): 781–790 doi: 10.1016/j.solener.2006.09.004
Yang Shaohai. Survey study on kangs. Inproceedings of civil and architectural institute of northern China,Harbin, 1963 (in Chinese)
Deguchi K, Sanda T. Thermal environmentof private houses with traditional heating system in northern China. Summaries of Technical Papers of Annual MeetingArchitectural Institute of Japan, Japan, 2002, 583–584
DeST Group of TsinghuaUniversity. Building environmental systemsimulation and analysis-DeST. Beijing: China Architecture Industry Press, 2006 (in Chinese)
Li Y, Delsante A. Natural ventilation induced by combined wind and thermal forces. Building and Environment, 2001, 36(1): 59–71 doi: 10.1016/S0360-1323(99)00070-0
Andersen K. Theory for natural ventilation by thermal buoyancy inone zone with uniform temperature. Buildingand Environment, 2003, 38(11): 1281–1289 doi: 10.1016/S0360-1323(03)00132-X
Patankar S V. Numerical Heat Transfer and Fluid Flow. Washington: Hemisphere PublishingCorporation, 1980
Zhuang Zhi, Li Yuguo, Chen Bin. Smoke flows in Chinese kangs. Indoor and Built Environment, 2009, 18(3): 219–233 doi: 10.1177/1420326X09105454
Zhuang Zhi, Li Yuguo, Chen Bin. A mathematical model for a house integratedwith an elevated Chinese kang heating system. In the 10th International Building Performance Simulation AssociationConference and Exhibition, Beijing, 2007
Yan Da, Xia Jianjun,Tang Waiyin,Song Fangting,Zhang Xiaoliang,Jiang Yi. DeST—an integratedbuilding simulation toolkit part I: fundamentals. Building Simulation2008, 1(2): 95–110
Zheng Zhuling. Heating energy analysis and comparison of the typicalrural housing in northern China. Dissertationfor the Master’s Degree, Beijing: Tsinghua University, 2007 (in Chinese)
Zhuang Zhi. Smoke flow and thermal performance of Chinese kang. Dissertation for the Doctoral Degree. Dalian: DalianUniversity of Technology, 2009 (in Chinese)
Zhuang Zhi, Li Yuguo, Duanmu Lin, Wang Zongshan, Chen Bin, Qian Hua, Sun Yafeng, Zhao Yang, Liu Li. Experimental assessment of thermal performance of an elevated Chinesekang system. The First International Conferenceon Building Energy and Environment, Dalian, 2008
Guo Jiye. The structure of elevated kangs as well as material selection. New Agriculture, 2001, (3): 42–43 (in Chinese)
China Academy of BuildingResearch. Floor radiant heating technologyregulation (JGJ142-2004). Ministry of Housingand Urban-Rural Development of the people's Republic of China, 2004 (in Chinese)
Zhuang Z, Li Y, Chen B. Thermal storage performance analysison Chinese kangs. Energy and Buildings, 2009, 41(4): 452–459 doi: 10.1016/j.enbuild.2008.11.006
National MeteorologicalInformation Center and Department of Building Science of TsinghuaUniversity. China Special Climate Databasefor Building Thermal Environment Analysis. Beijing: China Architecture IndustryPress, 2005 (in Chinese)