Please wait a minute...
Frontiers in Energy

ISSN 2095-1701

ISSN 2095-1698(Online)

CN 11-6017/TK

邮发代号 80-972

2019 Impact Factor: 2.657

Front. Energy  2010, Vol. 4 Issue (1): 22-34   https://doi.org/10.1007/s11708-010-0024-y
  Research articles 本期目录
Case study of data-oriented approach for building energy performance investigation
Case study of data-oriented approach for building energy performance investigation
Jianjun XIA,He XIAO,Yi JIANG,
Building Energy Research Center, School of Architecture, Tsinghua University, Beijing 100084, China;
 全文: PDF(725 KB)  
Abstract:The key parameters that may influence building energy performance is studied by comparing the building energy data of college buildings in two different regions (the USA and China). By introducing data-orientated approach, a study of a set of on-campus building energy demand and consumption is conducted for cooling, heating and electricity. In addition, the heating, ventilation and air conditioning (HVAC) and lighting systems are studied in great detail. The breakdown analyses of the current energy consumption data are used to focus the investigation on critical issues. The analysis shows that the energy consumption of college buildings in the USA can be 3–5 times more than that of college buildings in China. The over-high energy consumption in campus buildings in the USA is mainly caused by operation schedule, system style, cooling and heating counteraction and sensor/actuator faults in the control systems, which also leads to the discussion of energy difference on the concept of “full control” or “local improvement” in building environment control. The study also indicates that the building energy efficiency can only be achieved by adjusting the demand according to natural conditions, encouraging green life behaviors, and developing relative technical solutions coordinated with the thrift culture and human behavior.
出版日期: 2010-03-05
 引用本文:   
. Case study of data-oriented approach for building energy performance investigation[J]. Front. Energy, 2010, 4(1): 22-34.
Jianjun XIA, He XIAO, Yi JIANG, . Case study of data-oriented approach for building energy performance investigation. Front. Energy, 2010, 4(1): 22-34.
 链接本文:  
https://academic.hep.com.cn/fie/CN/10.1007/s11708-010-0024-y
https://academic.hep.com.cn/fie/CN/Y2010/V4/I1/22
Weerasingho U G D, Ruwanpura J P. Integration of LEED rating system with the project management process. Proceedings of 31st Annual Conference of the CanadianSociety for Civil Engineering.Moncton, New Brunswick, 2008, 200–210
Chang C. Sensor FDD in re-commissioning: Methodology and application. 3rd Asia Pacific Conference on Building Commissioning.Hong Kong, 2008, 79–94
Building Energy ResearchCenter, Tsinghua University. 2009 AnnualReport on China Building Energy Efficiency. Beijing, 2009, 89
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed