Front. Mech. Eng.    2007, Vol. 2 Issue (3) : 301-304    https://doi.org/10.1007/s11465-007-0053-3
New method for computer numerical control machine tool calibration: Relay method
LIU Huanlao1, SHI Hanming2, LI Bin2, ZHOU Huichen2
1.Engineering Training Center of Guangdong Ocean University, Zhanjiang 524025, China; National CNC Control Research Center, Huazhong University of Science and Technology, Wuhan 430074, China; 2.National CNC Control Research Center, Huazhong University of Science and Technology, Wuhan 430074, China
 Download: PDF(396 KB)  
 Export: BibTeX | EndNote | Reference Manager | ProCite | RefWorks
Abstract Relay measurement method, which uses the kilogram-meter (KGM) measurement system to identify volumetric errors on the planes of computer numerical control (CNC) machine tools, is verified through experimental tests. During the process, all position errors on the entire plane table are measured by the equipment, which is limited to a small field. All errors are obtained first by measuring the error of the basic position near the original point. On the basis of that positional error, the positional errors far away from the original point are measured. Using this analogy, the error information on the positional points on the entire plane can be obtained. The process outlined above is called the relay method. Test results indicate that the accuracy and repeatability are high, and the method can be used to calibrate geometric errors on the plane of CNC machine tools after backlash errors have been well compensated.
Issue Date: 05 September 2007
 Cite this article:   
SHI Hanming,LIU Huanlao,LI Bin, et al. New method for computer numerical control machine tool calibration: Relay method[J]. Front. Mech. Eng., 2007, 2(3): 301-304.
 URL:  
https://academic.hep.com.cn/fme/EN/10.1007/s11465-007-0053-3
https://academic.hep.com.cn/fme/EN/Y2007/V2/I3/301