Please wait a minute...
Frontiers of Materials Science

ISSN 2095-025X

ISSN 2095-0268(Online)

CN 11-5985/TB

Postal Subscription Code 80-974

2018 Impact Factor: 1.701

Front. Mater. Sci.    2008, Vol. 2 Issue (4) : 386-391    https://doi.org/10.1007/s11706-008-0058-9
Effect of micro-characterization on thrombus formation ability of TiO film
JIANG Xiao-song1, CHEN Jun-ying2, HUANG Nan2
1.Key Laboratory for Advanced Technologies of Materials (Ministry of Education), School of Materials Science and Engineering, Southwest Jiaotong University;School of Materials Science and Engineering, Tongji University; 2.Key Laboratory for Advanced Technologies of Materials (Ministry of Education), School of Materials Science and Engineering, Southwest Jiaotong University;
 Download: PDF(318 KB)   HTML
 Export: BibTeX | EndNote | Reference Manager | ProCite | RefWorks
Abstract The thrombus formation ability of a biomedical microcoil for hemangioma treatment is one of the basic requirements in clinical intervention application. Surface modification of a biomedical microcoil can improve its thrombus formation ability. In this work, TiO2 films were deposited using the unbalanced magnetron sputtering method. The structures, components and micro-morphologies of the films were investigated by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), atomic force microscope (AFM), and scanning electron microscope (SEM). The thrombus formation ability of the films was studied by in vitro platelet adhesion test. The results indicated that a certain characteristic TiO2 film has the ability to increase thrombus formation. Furthermore, the biological behavior of cultured human umbilical vein endothelial cells (HUVECs) onto different films was investigated by an in vitro HUVECs cultured experiment. The results showed that endothelial cells on certain TiO2 film surfaces have good adherence, growth and proliferation. Additionally, the relationship between the micro-characterization and biological properties of TiO2 films is discussed.
Issue Date: 05 December 2008
 Cite this article:   
JIANG Xiao-song,CHEN Jun-ying,HUANG Nan. Effect of micro-characterization on thrombus formation ability of TiO film[J]. Front. Mater. Sci., 2008, 2(4): 386-391.
 URL:  
https://academic.hep.com.cn/foms/EN/10.1007/s11706-008-0058-9
https://academic.hep.com.cn/foms/EN/Y2008/V2/I4/386
1 Velten D, Biehl V, Aubertin F, et al.. Preparation of TiO2 layerson cp-Ti and Ti6Al4V by thermal and anodic oxidation and by sol-gelcoating techniques and their characterization. Journal of Biomedical Materials Research, 2002, 59(1): 18–28.
doi:10.1002/jbm.1212
2 Liu J-X, Yang D-Z, Shi F, et al.. Sol-gel deposited TiO2 film on NiTi surgical alloy for biocompatibility improvement. Thin Solid Films, 2003, 429(1–2): 225–230.
doi:10.1016/S0040-6090(03)00146-9
3 Tsyganov I, Maitz M F, Wieser E, et al.. Structure and properties of titanium oxide layersprepared by metal plasma immersion ion implantation and deposition. Surface and Coatings Technology, 2003, 174–175: 591–596.
doi:10.1016/S0257-8972(03)00687-X
4 O'Regan B, Gratzel M . A low-cost, high-efficiencysolar cell based on dye-sensitized colloidal TiO2 films. Nature, 1991, 353: 737–740.
doi:10.1038/353737a0
5 Jaffe E A, Nachman R L, Becker C G, et al.. Culture of human endothelial cells derived fromumbilical veins. Identification by morphologic and immunologic criteria. The Journal of Clinical Investigation, 1973, 52(11): 2745–2756.
doi:10.1172/JCI107470
6 Chen J Y, Wan G J, Leng Y X, et al.. Behavior of cultured human umbilical vein endothelialcells on titanium oxide films fabricated by plasma immersion ion implantationand deposition. Surface and Coatings Technology, 2004, 186(1–2): 270–276.
doi:10.1016/j.surfcoat.2004.02.050
7 Chen J Y, Leng Y X, Tian X B, et al.. Antithrombogenic investigation of surface energyand optical bandgap and hemocompatibility mechanism of Ti(Ta+5)O2 thin films. Biomaterials, 2002, 23(12): 2545–2552.
doi:10.1016/S0142-9612(01)00389-1
8 Xu L-X . The preparation and properties research of Ti-O films. Dissertation for the Master Degree.Chengdu: Southwest Jiaotong University, 2005, 92
9 Chen J Y, Wan G J, Leng Y X, et al.. Research on culture of human endothelial cellsand anticoagulant of Ti-O film. Sciencein China, Series E: Technological Sciences, 2005, 35(11): 1137–1144
10 Huang N, Yang P, Cheng X, et al.. Blood compatibility of amorphous titanium oxidefilms synthesized by ion beam enhanced deposition. Biomaterials, 1998, 19(7–9): 771–776.
doi:10.1016/S0142-9612(98)00212-9
11 Huang N, Yang P, Leng Y X, et al.. Hemocompatibility of titanium oxide films. Biomaterials, 2003, 24(13): 2177–2187.
doi:10.1016/S0142-9612(03)00046-2
12 Tunstall A, Rober C E, Morton D P . Comparison of tissue factor and prostacyclli productionby human umilical vein endothelial cells on Dacron vascular prothesesand Dacron smooth film. Journal of BiomedicalMaterials Research, 1994, 28: 1233–1238.
doi:10.1002/jbm.820281013
13 Miller D C, Thapa A, Haberstroh K M, et al.. Endothelial and vascular smooth muscle cellfunction on poly(lactic-co-glycolic acid) with nano-structured surfacefeatures. Biomaterials, 2004, 25(1): 53–61.
doi:10.1016/S0142-9612(03)00471-X
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed