Please wait a minute...
Frontiers of Structural and Civil Engineering

ISSN 2095-2430

ISSN 2095-2449(Online)

CN 10-1023/X

邮发代号 80-968

2019 Impact Factor: 1.68

Frontiers of Structural and Civil Engineering  2014, Vol. 8 Issue (3): 260-269   https://doi.org/10.1007/s11709-014-0261-y
  本期目录
Experimental analysis on strength and failure modes of wood beam-column connections
Zhenhua HUANG(),Sheldon Q SHI,Liping CAI
Deportment of Engineering Technology, University of North Texas, Denton, TX 76210, USA
 全文: PDF(4057 KB)   HTML
Abstract

This research experimentally examined the strength, failure modes, and behaviors of dowel-bearing and fiber-bearing wood beam-column connections and explored the effects of cyclic loading on the strength, failure modes, and behaviors of those connections. Base on limited numbers of exploratory laboratory tests (6 preliminary tests in total), the authors observed that the typical bolted connection (dowel-bearing type wood beam-column connection with fiber-bearing surfaces) showed good behavior (large peak moment) under the monotonic loads, and the tenon joint connection (fiber-bearing wood beam-column connection) showed good behavior under cyclic loads. The cyclic property of loading reduced the strength of the dowel-bearing type wood beam-column connections, but increased the strength of fiber-bearing type wood beam-column connections. More importantly, the authors identified a possible location of safety concern in current national design specifications (NDS) standards for the typical bolted connection (dowel-bearing connection with fiber bearing surface) under cyclic loading because the tested value was smaller than the NDS calculated value. But, because of the small amount of tests conducted, no final conclusion can be drawn based on those preliminary observations yet. A large number of repetitive laboratory tests should be conducted.

Key wordswood    connection    dowel-bearing    fiber-bearing
收稿日期: 2014-03-30      出版日期: 2014-08-19
Corresponding Author(s): Zhenhua HUANG   
 引用本文:   
. [J]. Frontiers of Structural and Civil Engineering, 2014, 8(3): 260-269.
Zhenhua HUANG,Sheldon Q SHI,Liping CAI. Experimental analysis on strength and failure modes of wood beam-column connections. Front. Struct. Civ. Eng., 2014, 8(3): 260-269.
 链接本文:  
https://academic.hep.com.cn/fsce/CN/10.1007/s11709-014-0261-y
https://academic.hep.com.cn/fsce/CN/Y2014/V8/I3/260
Fig.1  
Fig.2  
Fig.3  
Fig.4  
Fig.5  
test labelprotocolconnection configurationfastener typefastener spacinghold -down
1monotonictypical1/2″ × 7″ bolts w/washer4 1/2″none
2monotonicsimplified1/2″ × 5″ lag bolts w/owasher4 1/2″none
3monotonictenon jointnone-none
4cyclictypical1/2″ × 7″ bolts w/washer4 1/2″S/HD10S
5cyclicsimplified1/2″ × 5″ lag bolts w/owasher4 1/2″S/HD10S
6cyclictenon jointnone-S/HD10S
Tab.1  
Fig.6  
Fig.7  
Fig.8  
connectionmonotonic test (k-ft)cyclic test (k-ft)% difference
+M-M+M-M
typical2.5632.2051.221-14.0%-52.4%
simplified1.5171.3731.373-9.5%-9.5%
tenon joint2.0192.4272.256+ 20.2%+ 11.7%
Tab.2  
connectionmonotonic test (k-ft)cyclic test (k-ft)% difference
+M-M+M-M
typical2.5632.2051.221-14.0%-52.4%
simplified1.5171.3731.373-9.5%-9.5%
tenon joint2.0192.4272.256+ 20.2%+ 11.7%
Tab.3  
connectionNDS calculation (k-ft)monotonic test (k-ft)ratio
typical1.7682.5631.45
simplified0.9631.5171.58
tenon joint0.8962.0192.25
Tab.4  
test labelNDS calculation (k-ft)cyclic test (k-ft)ratio
+M-M+M-M+M-M
typical1.7681.3542.2051.2211.250.90
simplified0.9630.9631.3731.3731.431.43
tenon joint0.8960.8962.4272.2562.712.52
Tab.5  
Fig.9  
Fig.10  
Fig.11  
1 Li J. Ying Zao Fa Shi. Royal Press, Kaifeng, China (Song Dynasty), 1100 (in Chinese)
2 Ma B J. Construction Technology of Chinese Ancient Timber Architectures. 2nded. Beijing: Science Press, 2003 (in Chinese)
3 Song X, Lam F. Laterally braced wood beam-columns subjected to biaxial eccentric loading. Computers & Structures, 2009, 87(17–18): 1058–1066
4 Xing H, Xue S, Zong G. Dynamic properties of conventional beam-column timber structure under successive damage. Journal of Asian Architecture and Building Engineering, 2011, 202(1): 195–202
5 O’Loinsigh C, Oudjene M, Ait-Aider H, Fanning P, Pizzi A, Shotton E, Meghlat E M. Experimental study of timber-to-timber composite beam using welded-through wood dowels. Construction & Building Materials, 2012, 36: 245–250
6 Leijten A J M, Brandon D. Advances in moment transferring dvw reinforced timber connections- Analysis and experimental verification, Part 1. Construction & Building Materials, 2013, 43: 614–622
7 NDS. National Design Specification for Wood Construction ASD/LRFD. American Forest & Paper Association, Washington, DC, 2012
8 DCS. Deck Construction Specifications of the Building Department of the City of Lancaster, Lancaster, OH, 2004
9 ASTM E2126. Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Walls for Buildings, American Society for Testing and Materials, West Conshohocken, PA, 2007
Viewed
Full text


Abstract

Cited

  Shared   