Please wait a minute...
Frontiers of Structural and Civil Engineering

ISSN 2095-2430

ISSN 2095-2449(Online)

CN 10-1023/X

邮发代号 80-968

2019 Impact Factor: 1.68

Frontiers of Structural and Civil Engineering  2018, Vol. 12 Issue (4): 662-671   https://doi.org/10.1007/s11709-018-0512-4
  本期目录
The defect-length effect in corrosion detection with magnetic method for bridge cables
Qiwei ZHANG1,2(), Rongya XIN2
1. State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, China
2. Department of Bridge Engineering, Tongji University, Shanghai 200092, China
 全文: PDF(1015 KB)   HTML
Abstract

Quantitative evaluation of the steel corrosion in cables is significant for the safe operation of cable-supported bridges. The magnetic flux (MF) examination shows great potential to detect the corrosion defect, or loss of metallic cross-sectional area (LMA). An LMA defect in steel cables can be measured accurately when it is longer than a certain length. However, for defects in early stage, where the length of corrosion area is short, the MF examination may produce unacceptable error. In this study, the effect of defect length on the MF examination for corrosion detection of bridge cables is investigated through theoretical analysis and model experiments. An original analytical model to quantify the influence of defect length is proposed based on the equivalent magnetic circuit method. Then, MF examination experiments are performed on a series of cable models with different defect lengths and locations to verify the analytical model. Further, parameter study is conducted based on the proposed analytical model to clarify the mechanism of the defect-length effect. The results show that the area loss caused by short corrosion damage will be underestimated if the defect-length effect is neglected, and this effect can be quantified efficiently with the proposed analytical model.

Key wordsbridge cable    corrosion detection    defect length    MF examination    quantitative evaluation
收稿日期: 2018-04-16      出版日期: 2018-11-20
Corresponding Author(s): Qiwei ZHANG   
 引用本文:   
. [J]. Frontiers of Structural and Civil Engineering, 2018, 12(4): 662-671.
Qiwei ZHANG, Rongya XIN. The defect-length effect in corrosion detection with magnetic method for bridge cables. Front. Struct. Civ. Eng., 2018, 12(4): 662-671.
 链接本文:  
https://academic.hep.com.cn/fsce/CN/10.1007/s11709-018-0512-4
https://academic.hep.com.cn/fsce/CN/Y2018/V12/I4/662
Fig.1  
Fig.2  
Fig.3  
Fig.4  
Fig.5  
Fig.6  
Fig.7  
Fig.8  
parameter a value unit
MMF of the magnets Fm 18.5 kA
Lm 0.035 m
Dm 0.12 m
Lyo 0.3 m
Dyo 0.16 m
T 0.04 m
Lc 0.265 m
dw 0.007 m
relative permeability of the yoke, myo 1000 /
permeability of the steel wire, m0ms having B-H curve in Fig. 10 /
number of the wires, n 103 /
percentage of LMA depend on the defect /
defect location re/rc depend on the defect /
dww 0.0091 m
Tab.1  
Fig.9  
Fig.10  
Fig.11  
Fig.12  
1 Mcgogney C H, Landis E N. Magnetic flux leakage for bridge inspection. In: Nondestructive Testing Methods for Civil Infrastructure. New York: American Society of Civil Engineers, 1995, 31–44
2 Ebeling R M, White B C, Strom R W, Hite J, John  E. Assessing Corrosion Damage and Corrosion Progression in Multistrand Anchor Systems in Use at Corps Projects. US Army Corps of Engineers, Report No. ERDC TR-13–3. 2013
3 Wu X J, Yuan J M, Ben A R. A novel magnetic testing method for the loss of metallic cross-sectional area of bridge cables. International Journal of Applied Electromagnetics and Mechanics, 2012, 39(1): 195–201
4 Park S, Kim J, Lee C, Lee J J. Magnetic flux leakage sensing-based steel cable NDE technique. Shock and Vibration, 2014, 2014(2): 1–8
https://doi.org/10.1155/2014/929341
5 Dost Y, Apaydın N, Dedeoğlu E, Mackenzie D K, Akkol O Z. Non-destructive Testing of Bosphorus Bridges. In: Nondestructive Testing of Materials and Structures, Springer, 2013, 819–825
6 Kitagawa M, Suzuki S, Okuda M. Assessment of cable maintenance technologies for Honshu-Shikoku Bridges. Journal of Bridge Engineering, 2001, 6(6): 418–424
https://doi.org/10.1061/(ASCE)1084-0702(2001)6:6(418)
7 Liu X, Wang Y, Wu B, Gao Z, He C. Design of tunnel magnetoresistive-based circular MFL sensor array for the detection of flaws in steel wire rope. Journal of Sensors, 2016, 2016: 1–8
8 Reimund V, Pelkner M, Kreutzbruck M, Haueisen J. Sensitivity analysis of the non-destructive evaluation of micro-cracks using GMR sensors. NDT & E International, 2014, 64: 21–29
https://doi.org/10.1016/j.ndteint.2014.02.003
9 Weischedel H R, Hoehle H. Quantitative nondestructive in-service evaluation of stay cables of cable-stayed bridges: methods and practical experience. In: Proc. SPIE 2456, Nondestructive Evaluation of Aging Bridges and Highways, 1995
https://doi.org/10.1117/12.209768.
10 Weischedel H R. Electromagnetic wire rope inspection- resolution is important. Materials Evaluation, 1998, 56(11): 1297–1301
11 Zhang Q W, Xin R Y, Ji Y F. Corrosion detection for steel wires in bridge cables using magnetic method. In: IABSE Conference Nara 2015, Nara, 2015, Article ID: SS–1
12 Hamelin M, Kitzinger F. Apparatus for increasing linear resolution of electromagnetic wire rope testing. United States Patent No. 5,565,771
13 Weischedel H R. Electromagnetic wire rope inspection: signal generation, filtering and computer-aided rope evaluation. In: OIPEEC Technical Meeting on the Non-destructive Testing of Rope, Krakow, Poland, 1999, 91–104
14 The University Of Reading. Wire Rope Non-destructive Testing- Survey of Instrument Manufacturers. OFFSHORE TECHNOLOGY REPORT-OTO 2000 064. 2000
15 Jomdecha C, Prateepasen A. Design of modified electromagnetic main-flux for steel wire rope inspection. NDT & E International, 2009, 42(1): 77–83
https://doi.org/10.1016/j.ndteint.2007.10.006
16 Xu F, Wang X, Wu H. Inspection method of cable-stayed bridge using magnetic flux leakage detection: principle, sensor design, and signal processing. Journal of Mechanical Science and Technology, 2012, 26 (3): 661–669
17 Yuan J M. Measurement Methods for Metal Cross-sectional Area of in-service Cables. Dissertation for the Doctoral Degree. Wuhan: Huazhong University of Science & Technology, 2012 (in Chinese)
18 Geller L B, Rousseau G. Effect of Trapped Wire Rope Debris upon an EM Instrument's LMA Chart Trace. CANMET INFORMATION CENTER, Research Report No. MRL 90–008 (TR). 1990
19 Rumiche F, Indacochea J E, Wang M L. Detection and monitoring of corrosion in structural carbon steels using electromagnetic sensors. Journal of Engineering Materials and Technology, 2008, 130(3): 635–644
https://doi.org/10.1115/1.2931145
20 General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China. Technical Conditions for Hot-Extruding PE Protection High Strength Wire Cable of Cable-Stayed Bridge, GB/T 18365-2001. Beijing: China Standards Press, 2001 (in Chinese)
21 Christen R, Bergamini A, Motavalli M. Three-dimensional localization of defects in stay cables using magnetic flux leakage methods. Journal of Nondestructive Evaluation, 2003, 22 (3): 93–101
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed