Please wait a minute...
Frontiers of Structural and Civil Engineering

ISSN 2095-2430

ISSN 2095-2449(Online)

CN 10-1023/X

邮发代号 80-968

2019 Impact Factor: 1.68

Frontiers of Structural and Civil Engineering  2024, Vol. 18 Issue (11): 1663-1679   https://doi.org/10.1007/s11709-024-1109-8
  本期目录
Research on the method of construction disturbance zoning for shield tunnel approaching to urban structures
Ziyang ZHOU1, Fukang GUO1, Jianzhong NI2, Kun FENG1(), Jingxuan ZHANG1, Yiwen LIU1
. Key Laboratory of Transportation Tunnel Engineering of Ministry of Education, Southwest Jiaotong University, Chengdu 610031, China
. Hangzhou Fuyang City Construction Investment Group co., Ltd., Hangzhou 310000, China
 全文: PDF(5093 KB)   HTML
Abstract

This paper presents a calculation method that evaluates the extent of disturbance based on structural safety limits. Additionally, it summarizes the assessment methods for construction disturbance zones in shield tunneling near pile foundations, urban ground structures, and underground structures. Furthermore, taking the construction of the Chengdu Jinxiu Tunnel under bridges and urban pipelines as the engineering background, a study on the disturbance zoning of adjacent structures was conducted. The most intense disturbance occurs within one week of the tunnel underpass process, and it has a significant impact within a range of two times the tunnel diameter along the tunnel axis. The bridge pile and bridge deck experience less disturbance from tunnel approaching construction, with a maximum disturbance zone characterized as medium disturbance. On the other hand, underground pipelines are subjected to more significant disturbances from tunnel construction, with a maximum disturbance zone classified as strong disturbance. The implementation of “bridge pile sleeve valve pipe grouting & underground pipeline ground grouting & tunnel advance grouting” in the field effectively limits the vertical settlement of bridges and pipelines, resulting in a decrease of approximately 0.1 in disturbance level for the structures. The disturbance zoning method can assess tunnel disturbance with structures, identify high-risk interference locations, and facilitate targeted design reinforcement solutions.

Key wordsshield tunnel    approaching construction    field monitoring    disturbance zoning method
收稿日期: 2023-11-06      出版日期: 2024-11-28
Corresponding Author(s): Kun FENG   
 引用本文:   
. [J]. Frontiers of Structural and Civil Engineering, 2024, 18(11): 1663-1679.
Ziyang ZHOU, Fukang GUO, Jianzhong NI, Kun FENG, Jingxuan ZHANG, Yiwen LIU. Research on the method of construction disturbance zoning for shield tunnel approaching to urban structures. Front. Struct. Civ. Eng., 2024, 18(11): 1663-1679.
 链接本文:  
https://academic.hep.com.cn/fsce/CN/10.1007/s11709-024-1109-8
https://academic.hep.com.cn/fsce/CN/Y2024/V18/I11/1663
Fig.1  
Type of bridge Deflection limits
Simply supported or continuous truss L/500
Simply supported or continuous slab beam L/500
The cantilever end of the beam L1/500
Main beam of cable-stayed bridge L/400
Suspension bridge stiffening beam L/250
Tab.1  
Deformation characteristics of buildings Disturbance limits of medium and low compressibility soil Disturbance limits of high compressible soil
Local inclination of masonry load-bearing structure foundation 0.002 0.003
Settlement difference between adjacent column foundations of industrial and civil buildings
 (1) Framework structure 0.002l 0.003l
 (2) Side row columns filled with masonry walls 0.0007l 0.001l
 (3) Structures where differential settlement does not generate additional stress 0.005l 0.005l
Settlement of column foundation in single-layer truss structure (column spacing of 6m) (mm) 120 200
Tab.2  
The overall inclination of high-rise buildings Disturbance limits
Hg≤ 24 m 0.004
24 m < Hg≤ 60 m 0.003
60 m < Hg≤ 100 m 0.0025
Hg > 100 m 0.002
The average settlement of a simple high-rise building foundation (mm) 200
Tab.3  
The inclination of high-rise structural foundations Disturbance limits
Hg≤ 20 m 0.008
20 m < Hg≤ 50 m 0.006
50 m < Hg≤ 100 m 0.005
100 m < Hg≤ 150 m 0.004
150 m < Hg≤ 200 m 0.003
200 m < Hg≤ 250 m 0.002
Tab.4  
Settlement of high-rise structure foundation (mm) Disturbance limits
Hg≤ 100 m 400
100 m < Hg≤ 200 m 300
200 m < Hg≤ 250 m 200
Tab.5  
Tunnel disturbance control quantity Allowable disturbance (mm)
Vertical displacement of tunnel 10–20
Horizontal displacement of tunnel 5–10
Differential settlement of tunnels 0.04%Lt
Tab.6  
Fig.2  
Fig.3  
Fig.4  
Fig.5  
Fig.6  
Fig.7  
Fig.8  
Fig.9  
Strata and materials Elastic modulus (MPa) Density (kg/m3) Poisson’s ratio Internal friction angle (° ) Cohesive force (kPa) Tensile strength (kPa)
Fill 3.87 1800 0.3 7 12 60
Silty mudstone 36 2030 0.25 35 50 500
Segment-C50 concrete 34500 2500 0.2
Bridge Piles-C30 concrete 30000 2420 0.2
Bridge deck-C40 concrete 32500 2450 0.2
Grouting material 400 1740 0.25
Underground pipeline 200000 7850 0.18
Tab.7  
Fig.10  
Fig.11  
Fig.12  
Fig.13  
Fig.14  
Fig.15  
Parameters Value
Underground pipeline diameter, D 170 mm
Bridge span spacing, L 30 m
Pile-Importance coefficient 1.1
Bridge deck-Importance coefficient 1.1
Underground pipeline-Importance coefficient 1
Pile-allowable stress increment 5 MPa
Pile-allowable vertical displacement 20 mm
Pile-allowable lateral displacement 6 mm
Bridge-allowable deflection 30 mm
Underground pipeline-allowable vertical displacement 5.1 mm
Tab.8  
Disturbance level Single pile disturbance Bridge deck disturbance Underground pipeline disturbance Disturbance extent
A (0.8,1.1] (0.8,1.1] (0.8,1.0] extremely strong disturbance
B (0.6,0.8] (0.6,0.8] (0.6,0.8] strong disturbance
C (0.4,0.6] (0.4,0.6] (0.4,0.6] medium disturbance
D (0.2,0.4] (0.2,0.4] (0.2,0.4] weak disturbance
E (0,0.2] (0,0.2] (0,0.2] extremely weak disturbance
Tab.9  
Fig.16  
Fig.17  
Fig.18  
Fig.19  
Fig.20  
Fig.21  
1 C Liu, Z X Zhang, C Y Kwok, H Q Jiang, L Teng. Ground responses to tunneling in soft soil using the URUP method. Journal of Geotechnical and Geoenvironmental Engineering, 2017, 143(7): 04017023
https://doi.org/10.1061/(ASCE)GT.1943-5606.0001695
2 Z Huang, C Zhang, H Fu, H Deng, S Ma, J Fu. Numerical study on the disturbance effect of short-distance parallel shield tunnelling undercrossing existing tunnels. Advances in Civil Engineering, 2020, 2020: 8810658
https://doi.org/10.1155/2020/8810658
3 R Liang, T Xia, Y Hong, F Yu. Effects of above-crossing tunnelling on the existing shield tunnels. Tunnelling and Underground Space Technology, 2016, 58: 159–176
https://doi.org/10.1016/j.tust.2016.05.002
4 J Wang, P Zhou, Z Song, S Li, Q Zhang. A new calculation method for tunneling-caused stratum settlement. KSCE Journal of Civil Engineering, 2022, 26(6): 2624–2640
https://doi.org/10.1007/s12205-022-1258-z
5 Q Zhu, Y Ding. Impact of new undercrossing tunnel excavation on the stability of the existing tunnel. Frontiers of Earth Science, 2022, 10(6): 1–12
6 M Huang, C Zhang, Z Li. A simplified analysis method for the influence of tunneling on grouped piles. Tunnelling and Underground Space Technology, 2009, 24(4): 410–422
https://doi.org/10.1016/j.tust.2008.11.005
7 H Hu, Y Zhu, G Zhang, H Zhang, P Tu. The environmental effects induced by a metro shield tunnel side-crossing on adjacent pile foundations and its impact partition. Advances in Civil Engineering, 2021, 2021: 8216724
https://doi.org/10.1155/2021/8216724
8 J Zhou, Z Sun, B Wei, L Zhang, P Zeng. Deflection-based multilevel structural condition assessment of long-span prestressed concrete girder bridges using a connected pipe system. Measurement, 2021, 169(4): 108352
https://doi.org/10.1016/j.measurement.2020.108352
9 J Li, Q Fang, X Liu, J Du, G Wang, J Wang. Mechanical behaviors of existing large-diameter tunnel induced by horseshoe-shaped undercrossing twin tunnels in gravel. Applied Sciences, 2022, 12(14): 7344
https://doi.org/10.3390/app12147344
10 X Ou, Y Liu, C Li, X Zhou, Q Chen, Y Zhou, Q Zhang. Analysis of the interaction effects of shield structure oblique passing under an existing tunnel. Applied Sciences, 2022, 12(11): 5569
https://doi.org/10.3390/app12115569
11 X Lan, X Zhang, X Li, Z Li, Y Liu, M Xia. Model experiment on surface subsidence induced by excavation of shallow small-spacing tunnels. Environmental Earth Sciences, 2022, 81(4): 133
https://doi.org/10.1007/s12665-022-10226-x
12 D Zhang, B Liu, Y Qin. Construction of a large-section long pedestrian underpass using pipe jacking in muddy silty clay: A case study. Tunnelling and Underground Space Technology, 2016, 60: 151–164
https://doi.org/10.1016/j.tust.2016.08.009
13 T Boonyarak, K W W Phisitkul, C Ng, W Teparaksa, Z Z Aye. Observed ground and pile group responses due to tunneling in Bangkok stiff clay. Canadian Geotechnical Journal, 2014, 51(5): 479–495
https://doi.org/10.1139/cgj-2013-0082
14 Z Yang, X Wang. Influence of metro tunnel excavation on deformation of existing pedestrian underpass in Changzhou railway station platform. IEEE Access: Practical Innovations, Open Solutions, 2020, 8: 55860–55871
https://doi.org/10.1109/ACCESS.2020.2981343
15 G Song, A M Marshall. Centrifuge study on the influence of tunnel excavation on piles in sand. Journal of Geotechnical and Geoenvironmental Engineering, 2020, 146(12): 04020129
https://doi.org/10.1061/(ASCE)GT.1943-5606.0002401
16 C J Lee. Three-dimensional numerical analyses of the response of a single pile and pile groups to tunnelling in weak weathered rock. Tunnelling and Underground Space Technology, 2012, 32: 132–142
https://doi.org/10.1016/j.tust.2012.06.005
17 L T Chen, H G Poulos, N Loganathan. Pile responses caused by tunneling. Journal of Geotechnical and Geoenvironmental Engineering, 1999, 125(3): 207–215
https://doi.org/10.1061/(ASCE)1090-0241(1999)125:3(207
18 Z Zhang, M Zhang, Q Zhao. A simplified analysis for deformation behavior of buried pipelines considering disturbance effects of underground excavation in soft clays. Arabian Journal of Geosciences, 2015, 8(10): 7771–7785
https://doi.org/10.1007/s12517-014-1773-4
19 X Yan, Z Sun, S Li, R Liu, Q Zhang, Y Zhang. Quantitatively assessing the pre-grouting effect on the stability of tunnels excavated in fault zones with discontinuity layout optimization: A case study. Frontiers of Structural and Civil Engineering, 2019, 13(6): 1393–1404
https://doi.org/10.1007/s11709-019-0563-1
20 H Yu, X Chen, Y Sun. A generalized bond-based peridynamic model for quasi-brittle materials enriched with bond tension–rotation–shear coupling effects. Computer Methods in Applied Mechanics and Engineering, 2020, 372: 113405
21 L Jing, C Y Kwok, Y F Leung. Micromechanical origin of particle size segregation. Physical Review Letters, 2017, 118(11): 1–5
https://doi.org/10.1103/PhysRevLett.118.118001
22 F Meng, R Chen, X Kang. Effects of tunneling-induced soil disturbance on the post-construction settlement in structured soft soils. Tunnelling and Underground Space Technology, 2018, 80: 53–63
https://doi.org/10.1016/j.tust.2018.06.007
23 Y Mahmutoǧlu. Surface subsidence induced by twin subway tunnelling in soft ground conditions in Istanbul. Bulletin of Engineering Geology and the Environment, 2011, 70(1): 115–131
https://doi.org/10.1007/s10064-010-0289-8
24 D Liu, X Liu, Z Zhong, Y Han, F Xiong, X Zhou. Realization of super-large-diameter slurry shield passing through settlement-sensitive area based on unreinforced disturbance control technology. Computational Intelligence and Neuroscience, 2022, 2022: 6299645
https://doi.org/10.1155/2022/6299645
25 T Ren, H Zhang, Y Guo, Y Tang, Q Li. Numerical simulation of ground surface settlement of underpass building in tunnel boring machine double-line tunnels. Frontiers of Earth Science, 2022, 10: 1–11
26 F Sun, Z Jin, C Wang, C Gou, X Li, C Liu, Z Yu. Case study on tunnel settlement calculations during construction considering shield disturbance. KSCE Journal of Civil Engineering, 2023, 27(5): 2202–2216
https://doi.org/10.1007/s12205-023-0925-z
27 Z Zhu, Q Sheng, Y Zhang, S Liu. Numerical modeling of stress disturbance characteristics during tunnel excavation. Advances in Materials Science and Engineering, 2020, 2020: 4508905
https://doi.org/10.1155/2020/4508905
28 C WangZ PengC GouK FengW Wu H Lin. Study on the influence zone partition method of shield tunnel-pile foundations approaching construction. China Civil Engineering Journal, 2017, 50: 174–181 (in Chinese)
29 Japan Railway Joint Technology Research Institute. Manual for Construction Work of Existing Tunnel, 1995
30 94-2008 JGJ. Technical Code for Building Pile Foundations. Beijing: Ministry of Housing and Urban-Rural Development of the People’s Republic of China, 2008 (in Chinese)
31 3362-2018 JTG. Specifications for Design of Highway Reinforced Concrete and Prestressed Concrete Bridges and Culverts. Beijing: Ministry of Transport of the People’s Republic of China, 2018 (in Chinese)
32 GB/50007-2011. Code for Design of Building Foundation. Beijing: Ministry of Housing and Urban-Rural Development of the People’s Republic of China, 2011 (in Chinese)
33 50332-2002 GB. Structural Design Code for Pipelines of Water Supply and Waste Water Engineering. Beijing: Ministry of Housing and Urban-Rural Development of the People’s Republic of China, 2002 (in Chinese)
34 51438-2021 GB/T. Design Standards for Shield Tunnel Engineering. Beijing: Ministry of Housing and Urban-Rural Development of the People’s Republic of China, 2021 (in Chinese)
35 50068-201 GB8. Unified Standard for Reliability Design of Building Structures. Beijing: Ministry of Housing and Urban-Rural Development of the People’s Republic of China, 2018 (in Chinese)
36 C Liu, Z Zhang, R A Regueiro. Pile and pile group response to tunnelling using a large diameter slurry shield—Case study in Shanghai. Computers and Geotechnics, 2014, 2014(59): 21–43
https://doi.org/10.1016/j.compgeo.2014.03.006
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed