A performance analysis of integrated solid oxide fuel cell and heat recovery steam generator for IGFC system
Souman RUDRA1,H. T. KIM1,Jinwook LEE2,L. ROSENDAHL3,
1.Division of Energy System Research, Graduate School, Ajou University, Suwon 443-749, Korea; 2.Plant Engineering Center, Institute of Advance Engineering, Suwon 443-749, Korea; 3.Department of Energy Technology, Aalborg University, DK-9220, Denmark;
 Download: PDF(474 KB)  
 Export: BibTeX | EndNote | Reference Manager | ProCite | RefWorks
Abstract Solid oxide fuel cell (SOFC) is a promising technology for electricity generation. Sulfur-free syngas from a gas-cleaning unit serves as fuel for SOFC in integrated gasification fuel cell (IGFC) power plants. It converts the chemical energy of fuel gas directly into electric energy, thus high efficiencies can be achieved. The outputs from SOFC can be utilized by heat recovery steam generator (HRSG), which drives the steam turbine for electricity production. The SOFC stack model was developed using the process flow sheet simulator Aspen Plus, which is of the equilibrium type. Various ranges of syngas properties gathered from different literature were used for the simulation. The results indicate a trade-off efficiency and power with respect to a variety of SOFC inputs. The HRSG located after SOFC was included in the current simulation study with various operating parameters. This paper describes IGFC power plants, particularly the optimization of HRSG to improve the efficiency of the heat recovery from the SOFC exhaust gas and to maximize the power production in the steam cycle in the IGFC system. HRSG output from different pressure levels varies depending on the SOFC output. The steam turbine efficiency was calculated for measuring the total power plant output. The aim of this paper is to provide a simulation model for the optimal selection of the operative parameters of HRSG and SOFC for the IGFC system by comparing it with other models. The simulation model should be flexible enough for use in future development and capable of predicting system performance under various operating conditions.
Keywords SOFC      HRSG      IGFC      syngas      
Issue Date: 05 September 2010
 Cite this article:   
Souman RUDRA,Jinwook LEE,H. T. KIM, et al. A performance analysis of integrated solid oxide fuel cell and heat recovery steam generator for IGFC system[J]. Front. Energy, 2010, 4(3): 402-413.
 URL:  
https://academic.hep.com.cn/fie/EN/10.1007/s11708-010-0122-x
https://academic.hep.com.cn/fie/EN/Y2010/V4/I3/402
U S NationalEnergy Technology Laboratory. IntegratedGasification Fuel Cell Performance and Cost Assessment. DOE/NETL-2009/1361, 2009
Wantanabe T, Maeda S. Trends and outlook in high-temperature fuel cells for clean coal technology. Quarterly Review, 2007, (23): 65–78
www.netl.doe.gov/publications/proceedings/09/seca/posters/Brouwerl_Poster.pdf
Harvey S P, Richter H J. A detailed study of a gas turbine cycle with an integrated internalreforming solid oxide fuel cell. In: Proceedings of 29th Intersociety Energy Conversion Engineering Conference, Monterey,CA, 1994, 961–973
Costamagna P, Magistri L, Massardo A F. Design and part-load performanceof a hybrid system based on a solid oxide fuel cell reactor and amicro gas turbine. Journal of Power Sources, 2001, 96(2): 352–368

doi: 10.1016/S0378-7753(00)00668-6
George R A. Status of tubular SOFC field unit demonstrations. Journal of Power Sources, 2008, 6(1―2): 134–139
Calisea F, Dentice d’Accadiaa M, Palomboa A, Vanoli L. Simulation and exergy analysis of a hybrid solid oxidefuel cell (SOFC)—Gas turbine system. Energy, 2006, 31(15): 3278–3299

doi: 10.1016/j.energy.2006.03.006
Mahagaokar U, Egon L D. High heat recovery in coal and coke gasification combined gasification system. ASME Paper 95-GT-259, 1995
Jiang L, Lin R, Jin H, Cai R, Liu Z. Study on thermodynamic character and optimization of steam cycle system in IGCC. Energy, 2002, 43(9―12): 1339–1348
Zhu H, Kee R, Zhu H Y, Kee R J. Thermodynamics of SOFC efficiency and fuel utilization as functionsof fuel mixtures and operating conditions. Journal of Power Sources, 2006, 161(2): 957–964

doi: 10.1016/j.jpowsour.2006.05.006
Campanari S. Thermodynamic model and parametric analysis of a tubularSOFC module. Journal of Power Sources, 2001, 92(1,2): 26–34
Suwanwarangkul R, Croiset E, Pritzker M D, Fowler M W, Douglas P L, Entchev E. Modeling of a cathode-supportedtubular solid oxide fuel cell operation with biomass-derived synthesisgas. Journal of Power Sources, 2007, 166(2): 386–399

doi: 10.1016/j.jpowsour.2006.12.096
Souman R, Kim H T, Wang H Y, Lee J W. Thermodynamic and exergy optimization of the operative parametersfor the heat recovery steam generator in IGCC power plant. IGEC-IV, Beijing, China, 2008, 68–72
Erbes M R, Eustis R H. A computer methodology for predicting design and off-design performanceof utility steam turbine generators. In: Proc American Power Conf, Chicago, Illinois, 1986
Spencer R C, Cotton K C, Cannon C N. A method of predicting theperformance of steam turbine-generators. ASME Power Division, 1963, Paper No. 62-WA-209
Pietro P D, Gerdes K. Integrated Gasification Fuel Cell Performance. DOE/NETL2009, 2009
[1] S. Rupesh, C. Muraleedharan, P. Arun. Energy and exergy analysis of syngas production from different biomasses through air-steam gasification[J]. Front. Energy, 2020, 14(3): 607-619.
[2] Abdalla M. ABDALLA, Shahzad HOSSAIN, Pg MohdIskandr PETRA, Mostafa GHASEMI, Abul K. AZAD. Achievements and trends of solid oxide fuel cells in clean energy field: a perspective review[J]. Front. Energy, 2020, 14(2): 359-382.
[3] Jiahui JIN, Lei WANG, Mingkai FU, Xin LI, Yuanwei LU. Thermodynamic assessment of hydrogen production via solar thermochemical cycle based on MoO2/Mo by methane reduction[J]. Front. Energy, 2020, 14(1): 71-80.
[4] S. NIKBAKHT NASERABAD,K. MOBINI,A. MEHRPANAHI,M. R. ALIGOODARZ. Exergy-energy analysis of full repowering of a steam power plant[J]. Front. Energy, 2015, 9(1): 54-67.
[5] Huisheng ZHANG, Shilie WENG, Ming SU. Performance comparison of cocurrent and countercurrent flow solid oxide fuel cells[J]. Front Energ, 2011, 5(2): 207-213.
[6] Yuzhang WANG, Shilie WENG, Yiwu WENG. Numerical investigation of the chemical and electrochemical characteristics of planar solid oxide fuel cell with direct internal reforming[J]. Front Energ, 2011, 5(2): 195-206.
[7] Yang LI, Yiwu WENG, Shilie WENG. Part-load, startup, and shutdown strategies of a solid oxide fuel cell-gas turbine hybrid system[J]. Front Energ, 2011, 5(2): 181-194.
[8] Zhe WANG , Jinning YANG , Zheng LI , Yong XIANG , . Syngas composition study[J]. Front. Energy, 2009, 3(3): 369-372.
[9] Xiaohong HE, Ruixian CAI. Typical off-design analytical performances of internal combustion engine cogeneration[J]. Front Energ Power Eng Chin, 2009, 3(2): 184-192.
[10] Fuchen WANG , Xinwen ZHOU , Wenyuan GUO , Zhenghua DAI , Xin GONG , Haifeng LIU , Zunhong YU , . Process analysis of syngas production by non-catalytic POX of oven gas[J]. Front. Energy, 2009, 3(1): 117-122.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed