Modeling of semi-rigid beam-to-column steel joints under extreme loading
C FANG, B A IZZUDDIN, A Y ELGHAZOULI, D A NETHERCOT
Front Struc Civil Eng. 2013, 7 (3): 245-263.
https://doi.org/10.1007/s11709-013-0215-9
Joints play an important role in providing ductility for steel-composite structures subject to extreme loading conditions, such as blast, fire and impact. Due to sound energy dissipation capability and fabrication efficiency, semi-rigid joints have increasingly received attention during the last decade. This paper presents a component approach for modeling semi-rigid beam-to-column joints based on Eurocode3, where the post-elastic response, including component strain hardening and ultimate rotational capacity, is also considered. Failure criteria are defined based on the ultimate deformation capacity of components and bolt-rows. The model enables a direct integration of joint response into global frame models with the consideration of axial deformability, such that the interaction between bending moment and axial force within the joints can be realistically captured. In addition, elevated temperature can be considered in the joint model via the degradation of the component response. Through comparisons with available test data, the joint model is shown to have good accuracy, and the failure criteria are found to be reliable yet conservative. The strain hardening response of components is shown to have significant influence on the ultimate bending capacity of the joints, while neglecting it usually leads to a conservative prediction.
Figures and Tables |
References |
Related Articles |
Metrics
|
|
Performance study on T-stub connected semi-rigid joint between rectangular tubular columns and H-shaped steel beams
Guochang LI, Hongping YU, Chen FANG
Front Struc Civil Eng. 2013, 7 (3): 296-303.
https://doi.org/10.1007/s11709-013-0217-7
This paper investigates the performance of T-stub connected semi-rigid joint of rectangular tubular columns and H-shaped steel beams. The finite element analysis software ABAQUS is used to analyze the nonlinear performance of the joint under monotonic loading. Meanwhile, the dimensions of T-stub, column and beam are considered as analytic parameters to discuss the performance of the joint. The analysis shows that the thickness and the length of T-stub webs, the height of beam section, bolt diameter, shear connector and the preloaded force affect the performance of the joint largely, and the thickness of the steel tube, the thickness and length of T-stub flange, bolt spacing have relatively little influences on the performance of the joint. The research results indicate that this joint is semi-rigid joint.
Figures and Tables |
References |
Related Articles |
Metrics
|
|
Numerical simulation of multi-body floating piers to investigate pontoon stability
Mostafa Shahrabi, Khosrow Bargi
Front Struc Civil Eng. 2013, 7 (3): 325-331.
https://doi.org/10.1007/s11709-013-0209-7
The objective of this study is to develop a procedure to analyze the motions of a floating pier comprised of several pontoons that are modeled as rigid bodies and connected to each other by flexible and rigid connectors. Recently, the use offloating piers has increased because of their advantages, such as faster and higher-quality construction, seismic force isolation for a full-scale mooring system, low dependence on local soil conditions and tides, ability to relocate or reconfigure the pier modules during the operation period and 75-100 years of repair-free service. A floating pier consists of a pier, access bridge, mooring system and fender system, each of which comes in many variations to suit different usages and construction considerations. The typical loads used in the design of these piers are dead loads, live loads, mooring loads, fender loads and environmental loads induced by wind, currents and waves. For numerical simulation, three types of piers are used: passenger piers, light-cargo piers and semi-heavy-cargo piers. The selected piers consist of several large pontoons joined by pivots and have a pile-based mooring system. These piers are modeled by SAP2000software as two-dimensional frames that are linked together. As the first step, each type of pier is subjected to loading, and its general behavior is assessed. According to this behavior, the major load combinations are described for the design of piers and analyzed to determine the behavior of the modules. Lastly, according to the analysis results and the safe use and stability considerations, such as the maximum draft and longitudinal gradient, the dimensions of each module in each pier type are presented.
References |
Related Articles |
Metrics
|
|
Evaluation of potential failure of rock slope at the left abutment of Jinsha River Bridge by model test and numerical method
Zhiming ZHAO, Xihua WANG
Front Struc Civil Eng. 2013, 7 (3): 332-340.
https://doi.org/10.1007/s11709-013-0206-x
Jinsha River Bridge is located on Tiger Leaping Gorge town, China. The left bank slope composes of moderately thick layer of slate overlain by schistose basalt, and where rocks are controlled by two sets of joint planes. To evaluate the stability of the rock slope under bridge foundation, model test and calculation model based on the geological parameters and the slope stability was simulated and analyzed using Universal Distinct Element Code (UDEC) and Finite Element Mehod (FEM). According to model test, failure mainly initiated at the toe with shear movement along the joint planes, eventually resulting in the sliding along the slope surface and formation of tension crack at the crest of the model. This result coincide with the UDEC model, which shows that slope surface will produce loosening damage and slipping expected along the joint planes under different loading conditions. Moreover, the result of FEM analysis indicates that the rock mass under the main pier has potential shear failure region. So, the bridge foundation should be strengthened to prevent the slope failure under external forces.
Figures and Tables |
References |
Related Articles |
Metrics
|
10 articles
|